Overview and Specifications
E
Electrical
Power supply voltage (Vs)
SELV/PELV 24 VDC±20% (ripple p-p 10% max.)
Current consumption
for more information.
Safety outputs (OSSD)
Two PNP or NPN transistor outputs (PNP or NPN is selectable by wiring of power
supply.)
Load current: 300 mA max., Residual voltage: 2 V max. (except for voltage drop due to
cable extension), Capacitive load: 1 µF max., Inductive load: 2.2 H max. *1 *2 *3
Leakage current: 1 mA max.(PNP), 2 mA max.(NPN) *4
*1. The load current is 150 mA max. when the operating ambient temperature is 45 to
55°C.
*2. The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.
*3. The load inductance is the maximum value when the safety output frequently
repeats ON and OFF.
When you use the safety output at 4 Hz or less, the usable load inductance
becomes larger.
*4. These values must be taken into consideration when connecting elements including
a capacitive load such as a capacitor.
Auxiliary output
One PNP or NPN transistor output (PNP or NPN is selectable by wiring of power
supply.)
Load current: 100 mA max., Residual voltage: 2 V max. *
* The residual voltage is 3 V max. when the Intelligent Tap is connected to the sensor.
Output
operation
mode
Safety output
Light-ON (Safety outputs are turned to the ON state when the receiver receives an
emitting signal.)
Auxiliary
output
Safety output (Inverted signal output: Enable) (default) (Configurable by SD Manager 3)
Input voltage
TEST
Light emission stops when connected to 24 VDC
ON voltage: Vs-3 V to Vs (short circuit current: approx.
5.0 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit
current: approx. 6.0 mA) *
Light emission stops when connected to 0 V
ON voltage: 0 to 3 V (short circuit current: approx. 6.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current:
approx. 5.0 mA) *
-
OPERATING
RANGE
SELECT
INPUT
-
Long: 12 V to Vs (short
circuit current: approx. 4.2
mA) * or open
Short: 0 to 3 V (short circuit
current: approx. 4.2 mA)
-
RESET/EDM
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 9.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 13.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 13.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 9.5 mA) *
MUTE A/B ,
PRE-RESET
PNP
ON voltage: Vs-3 V to Vs (short circuit current: approx. 4.5 mA) *
OFF voltage: 0 V to 1/2 Vs, or open (short circuit current: approx. 7.0 mA) *
NPN
ON voltage: 0 to 3 V (short circuit current: approx. 7.0 mA)
OFF voltage: 1/2 Vs to Vs, or open (short circuit current: approx. 4.5 mA) *
*The Vs indicates a supply voltage value in your environment.
Overvoltage category
(IEC 60664-1)
II
Indicators
1-4. LED Indicators on F3SG-SR/PG
for more information.
Protective circuit
Output short-circuit protection
Insulation resistance
20 M
or higher (500 VDC megger)
Dielectric strength
1,000 VAC, 50/60 Hz (1 min)
Model
F3SG-4PGA
-
A
F3SG-4PGA
-
L
F3SG-4PGA
-
C
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...