174
Ch
apt
e
r
3
Tea
c
h-
in
(F
ix Bla
n
king / Flo
a
ting
Blank
in
g
)
F3SG-SR/PG
User’s Manual
Setting with Intelligent Tap
*2 If the setting value is not an allowable one, the setting is invalid. The following cases are judged as invalid.
• The number of blanked beams is configured as nine (9) or more.
• The number of allowable beams is configured as three (3) or more.
• The number of blanked beams is the same as that of sensor beams.
• Number of allowable beams >= Number of blanked beams
• Teach-in is started when an object does not exist.
• Beam-blocked state is detected discontinuously in the Teach-in process.
• The blocking object is removed until the steps (4) to (5) are completed.
*3 If F3SG-SRA is used with the wired synchronization setting, the ABI indicator of the emitter for the area blocked by an object
turns ON red.
(6) Restart
<When operating the F3SG-SR with the Intelligent Tap not connected>
When completing the Teach-in setting, power off the F3SG-SR and remove the Intelligent Tap. Then
restart the F3SG-SR.
<When operating the F3SG-SR with the Intelligent Tap connected>
When completing the Teach-in setting, power off the F3SG-SR and set the DIP Switch Position 1 at
OFF (Unlock). Then restart the F3SG-SR.
There are two ways to restart.
• Power cycling
• Pressing and holding reset switch (for 1 s or longer): Set the DIP Switch Position 1 at OFF (Unlock).
(If restarting the F3SG-SR with the DIP Switch Position 1 set at ON (Lock), the configured zone will
be invalid. In this case, try the steps again from (4).)
After the restarting, the F3SG-SR waits for the Backup process of the settings. Perform the Backup
process. After the Backup process is complete, the power off the F3SG-SR and set the DIP Switch
Position 1 at ON (Lock). Check if the DIP Switch Positions 2 to 8 and other settings are configured as
intended, and then restart the F3SG-SR. After the F3SG-SR is restarted, the check if the Floating
Blanking zone and other settings are properly configured.
Refer to
for more information on the Backup procedure.
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...