12
Chapter
1
LED Indica
tor
s
on F3SG-SR/PG
F3SG-SR/PG
User’s Manual
Overview and Specifications
Shown below are indication statuses of the LED indicators on the F3SG-SR/PG when you purchased.
Emitter (F3SG-SR, F3SG-PGA-A/L)
*1. The indicator of the emitter is illuminated only in the case the Wired Synchronization is enabled and is off in the case the
Optical Synchronization is enabled.
*2. Configurable by SD Manager 3.
*3. This is the case for the Standard Muting mode. For other muting modes, refer to "
".
*4. The Area Beam Indicator closer to the "TOP" mark on the F3SG-SR blinks.
*5. The Area Beam Indicator closer to the "BTM" mark on the F3SG-SR blinks.
*6. DIP switches is on the Intelligent Tap.
Location Indicator
Name
Color
Illuminated
Blinking
F3SG
-SRA
F3SG
-SRB
F3SG-
PGA-A
F3SG-
PGA-L
1
Scan code
Green
Code A is selected
-
X
X
X
X
Orange Code B is selected
OFF
Automatic interference
prevention by wired
synchronization being
performed
2
Lockout
Red
LOCKOUT state. The
indicator is illuminated in
the emitter of another
sensor segment than that
having a lockout error
(when in cascade
connection or between the
emitter and receiver in the
Wired Synchronization)
LOCKOUT state. The indicator is
illuminated in the emitter of a sensor
segment having a lockout error
X
X
X
X
3
Operating
range
Green
Long Mode is selected
LOCKOUT state due to Operating
range selection setting error
X
X
-
X
OFF
Short Mode is selected
-
4
Test
Yellow
-
External Test is being performed
X
X
X
X
5
-
Area
Beam
Indicator
(ABI) (*1)
Green
The target beams of
the ABI are unblocked
and the safety outputs
are turned ON
MUTING or OVERRIDE state. In the
MUTING state, only the ABI
indicators in the muting zone are
blinking. Or the target beams of the
ABI are blocked instantaneously
X
-
X
X
Orange
Incident light level of
the target beams of the
ABI is 170% (factory
default setting (*2)) or
less of ON-threshold
(for 5 to 10 s)
Incident light level of the target beams of
the ABI is 170% (factory default setting
(*2)) or less of ON threshold 5 to 10 s
after illuminated when incident light level
of the target beams of the ABI is 170%
(factory default setting (*2)) or less of ON
threshold. Or one muting input becomes
the ON state and the MUTING state has
not been started yet, or one muting input
becomes the OFF state and the other is
not in the OFF state yet. (*3)
Red
The target beams of
the ABI are blocked
LOCKOUT state due to Cap error or Other
sensor error (*4), or LOCKOUT state due
to DIP Switch setting error (*5 *6)
OFF
The target beams of the
ABI are unblocked (The
ABI then will be
illuminated in green
when the safety outputs
are turned ON.)
-
6
TOP
Top-beam-
state (*1)
Blue
The top beam is
unblocked
MUTING/OVERRIDE state, or
LOCKOUT state due to Cap error or
Other sensor error
-
X
-
-
7
BTM
Bottom-
beam-
state (*1)
Blue
The bottom beam is
unblocked
MUTING/OVERRIDE, or LOCKOUT
state due to DIP Switch setting error (*6)
-
X
-
-
CODE
C
or
ERR
E
or
LONG
L
or
TEST
T
or
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...