172
Ch
apt
e
r
3
Tea
c
h-
in
(F
ix Bla
n
king / Flo
a
ting
Blank
in
g
)
F3SG-SR/PG
User’s Manual
Setting with Intelligent Tap
3-7-2. Setting Floating Blanking by Teach-in
Overview
You can teach-in the settings of the Floating Blanking by interrupting with an object to monitor by the
Floating Blanking. The Teach-in described in this chapter is performed with the Intelligent Tap
connected to the F3SG-SR and using the Push Switch or the Muting Input A.
Teach-in steps
Perform the Teach-in of the Floating Blanking based on the following steps.
(1) Connect Intelligent Tap to F3SG-SR
(2) Beam Alignment
(3) DIP Switch Setting
(4) Transition to Teach-in Mode
(5) Result Check Process
(6) Restart
(1) Connect Intelligent Tap to F3SG-SR
Connect the Intelligent Tap to the F3SG-SR.
(2) Beam Alignment
Perform the beam alignment for the F3SG-SR . In the case of the Optical Synchronization, install the
F3SG-SR so that the synchronization beams are clear.
For detailed beam adjustment steps, see
.
Misalignment during the Teach-in may result in an unintended setting or a failure of the Teach-in.
The factory default setting of the Teach-in Input is [Push Switch]. When selecting [Push Switch or external wiring], select
[Teach-in Input] – [Push Switch or external wiring] with the SD Manager 3 after the step (2), and then perform the
Restoration.
Refer to
for more information on setting this function by the SD Manager 3.
Refer to
4-2-7-3. Writing Configuration into Intelligent Tap
for more information on the Restoration by the SD Manager 3.
(3) DIP Switch Setting
Before powering F3SG-SR, set the DIP Switch of the intelligent tap as shown below, then power the
F3SG-SR.
• Set channel 1 to ON (Lock)
• Set channel 2 to ON (DIP Switch Enabled)
• Set channel 6 to OFF and channel 7 to ON (Floating Blanking Enabled)
The Intelligent Tap restores the settings configured by the DIP Switch, to the F3SG-SR. When the
Restoration process is complete is completed successfully, restart the F3SG-SR and check if the
F3SG-SR operates normally.
Block the target Floating Blanking zone by an object. Do not remove the object until the Step (5) is
complete.
The object must be no smaller than the object resolution.
Refer to
3-4. LED Indicators on Intelligent Tap
for more information.
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...