Setting with Intelligent Tap
70
1
Synchronization
method setting
R
1 byte
0: Optical sync. Scan code A
1: Optical sync. Scan code B
2: Wired sync.
3: Reserved.
2
External device
monitor setting
R
1 byte
1: Enable , 0: Disable
3
Interlock / Pre-
Reset / PSDI
setting
R
1 byte
0: Auto reset (both start and re-start interlock are disabled)
1: Start interlock is enabled.
2: Re-start interlock is enabled.
3: Manual reset (both start and re-start interlock are
enabled)
4: Pre-Reset is enabled.
5: PSDI single break
6: PSDI double break
The others: Reserved.
4
Blanking setting
R
1 byte
1: One of Fixed Blanking or Floating Blanking and Warning
zone setting is enabled.
0: Fixed Blanking, Floating Blanking and Warning zone
setting are disabled.
5
PNP / NPN setting
R
1 byte
1: PNP setting
0: NPN setting
6
Dip switch setting
R
1 byte
1: Enable
0: Disable (setting is done by Tool)
7
Muting status
R
1 byte
1: Under the MUTING state
0: The other
8
Override status
R
1 byte
1: Under the OVERRIDE state
0: The other
9
Muting sequence
error status
R
1 byte
1: Muting setting is active and sequence error occurs.
0: The other
10
Safety output status
R
1 byte
1: ON
0: OFF
11
Blanking bream
unblocked
information
R
1 byte
1: When Fixed-Blanking or Floating Blanking beams are
unblocked
0: The other
12
Push switch status
R
1 byte
1: ON
0: OFF
71
(Primary
sensor
Receiver)
0
Receiving light level
R
232 bytes
1byte x 232 beams
The incident light level data of each beam is output in 0 to
255 (8 bits) every beam (1 byte). *1
0 if the sensor is not connected or no light is received
72
(Secondary
sensor 1
Receiver)
0
Receiving light level
R
232 bytes
1byte x 232 beams
The incident light level data of each beam is output in 0 to
255 (8 bits) every beam (1 byte). *1
0 if the sensor is not connected or no light is received
73
(Secondary
sensor 2
Receiver)
0
Receiving light level
R
232 bytes
1byte x 232 beams
The incident light level data of each beam is output in 0 to
255 (8 bits) every beam (1 byte). *1
0 if the sensor is not connected or no light is received
80
0
Error code of
Intelligent Tap
R
48 bytes
(8 bytes
x 6)
Error code data is output in 8 bytes.
In order from upper to lower
1 byte: Error code
4 bytes: Power-ON Time (1 count every 15 minutes)
3 bytes: Data for inquiry*
Latest 6 records can be got.
* Please use the data for your inquiry.
*1. Defining the receiving light intensity level that turns ON the control output as 100%, the output is 22. Therefore, if the level is
170% and 90%, the output is 38 and 20, respectively.
Index
Sub-Index
Name
R/W
Length
Setting contents
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...