107
F3SG-SR/PG
User’s Manual
Chapter
2
O
ver
rid
e
System Operation and Functions
E
Timing chart
2-14-4. Setting with Intelligent Tap
The user cannot make any changes to this function by the DIP Switch.
2-14-5. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Setting the override time limit to infinite may cause a failure of disabling the OVERRIDE state when there is a failure of
the override input signal. Conduct risk assessment analysis thoroughly before enabling this setting.
Refer to
for more information on setting this function by the SD Manager 3.
Function
Initial value
Configurable value or numerical range
Override
Enable
Enable/Disable
Override input time limit
1 s
0.2 to 5 s in 0.1-s increments
Override time limit
600 s
1 to 600 s in 1-s increments, or infinite
RESET
O
N
OFF
O
V
ERRIDE state
Beam state
Un
b
locked
Blocked
Ena
b
led
Disa
b
led
OSSD
N
ote. In this timing chart, the O
V
ERRIDE state ends
w
hen the F3SG-SR/PG recei
v
es light.
T1: O
v
erride inp
u
t time limit
T2: O
v
erride time limit
O
N
OFF
T1 T1
T1 T1 T1
T1
O
N
OFF
Po
w
er
3 to 6 s
1 s max.
1 s max.
T2 max.
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...