5-4-3-10. Extending Cable Length with Commercially Available Cable
When you need to use a cable that is not specified by OMRON, use a cable that satisfies the following
specifications.
1. Emitter: 5-wire Receiver: 8-wire
2. 0.3 mm
2
or larger, conductor resistance 0.058 ohms/m max.
3. Mute A and Mute B lines, and 24V/0V and 0V/24V lines must be used as twisted-pair lines.
When using, for the Intelligent Tap, cables with a connector other than a straight type such as the L-
shaped, the cables may interfere with another cable or device or a mounting surface. Take notches or
shapes of the connectors into account in installing them.
Do not use cables in the same conduit as high voltage or electric power lines.