![background image](http://html1.mh-extra.com/html/omron/f3sg-pg-series/f3sg-pg-series_user-manual_741299379.webp)
349
F3SG-SR/PG
User’s Manual
Ch
apt
e
r
5
Mou
nti
ng
Wiring and Installation
E
3.
Fit the groove of the sensor's cap to the bracket (2), mount the bracket (1), and tighten the alignment
screws until the sensor no longer drops (Fig. 3).
4.
Power the emitter and receiver on to perform beam alignment (Fig. 4).
For more information on the beam alignment procedure, refer to
5-3-5. Beam Alignment Procedure
- There is no restriction in the angle adjustment range.
- For the way to distinguish the emitter from the receiver or distinguish the emitter/receiver from the passive mirror, refer
5-3-4-2. Mounting with Adjustable Side-Mount Brackets (Intermediate Brackets) (F39-LSGA)
Groo
v
e of the
sensor
'
s cap
Bracket (2)
Bracket (2)
Groo
v
e of the
sensor
'
s cap
Alignment
scre
w
s
Fig. 3
2. Lightly
tighten
Alignment
scre
w
s
2. Lightly
tighten
Fig. 4