57
F3SG-SR/PG
User’s Manual
Chapter
2
Self-Test
System Operation and Functions
E
2-5-1-2. Waveform of safety outputs
When the safety outputs are in the ON state, they are cyclically turned OFF as shown below to test the
output circuit. When this OFF signal is fed back, the output circuit is diagnosed as normal. If the output
signal does not include an OFF pulse signal due to short-circuit, etc, the receiver diagnoses a failure in
the output circuit or wiring, and it enters the LOCKOUT state.
OSSD 1
O
N
OFF
OSSD 2
O
N
OFF
F3SG-SR: ca. 140 to 620 ms
F3SG-PG: ca. 140 to 2
8
0 ms
F3SG-SR: ca. 70 to 310 ms
F3SG-PG: ca. 70 to 140 ms
*1. Approx. 20 to 90 ms
*1
*1
Approx. 40
u
s *4
*4. An OFF p
u
lse signal of safety o
u
tp
u
ts may extend to a
b
o
u
t 100
µ
s
d
u
e to the effect of the connected load (mostly capaciti
v
e load ).
*2
*3
*2. Signal
w
hen 2- or 3-segment cascade of F3SG-SR only
*3. Signal
w
hen 3-segment cascade of F3SG-SR only