![background image](http://html1.mh-extra.com/html/omron/f3sg-pg-series/f3sg-pg-series_user-manual_741299279.webp)
249
F3SG-SR/PG
User’s Manual
Chapter
4
Cha
nging Set
tings
with SD
Ma
nag
e
r 3
Setting with SD Manager 3
E
Zone setting is possible for desired channel and beam (in 1-beam increments).
The settings after the zone is determined are displayed in the zone information area under the chart.
• For more information on muting, refer to
.
• For more information on override, refer to
For the following functions, the setting parameters are kept individually in each case that the muting function is set
enabled or disabled. After changing the Muting function from Enable to Disable or from Disable to Enable, check the
settings of these functions again.
Affected functions: External Device Monitoring (EDM), Start Interlock, Restart Interlock, Auxiliary Output
For more information on the setting parameters, refer to:
2-11. External Device Monitoring (EDM)
When changing the settings is complete, confirm the settings and write the configuration to the F3SG-SR/PG.
To enable the written configuration, refer to
4-2-7-3. Writing Configuration into Intelligent Tap
When connecting the Intelligent Tap to a F3SG-SR/PG and trying to return the F3SG-SR/PG to [Detecting], follow step 4
of
4-1-3-2. Connection Procedure When Using USB Connector
to restart the F3SG-SR/PG and Intelligent Tap, or click
the [Monitor]
button.
Muting Setup Procedure
1.
Enable the Muting function (No. 1).
2.
Select a muting type (No. 2).
3.
Set up a zone (Refer to
below.) (Nos. 4, 5, and 6).
4.
As needed, set up the Dynamic Muting function (No. 7).
5.
As needed, set up the Statistics Data Recording function (No. 8).
6.
Set up muting time information (Refer to
Setting of Muting Time Information
below.) (No. 9).
7.
As needed, set up the Override function (No. 10).
8.
Click the [Write configuration] button. On the settings list which will appear, confirm that the changed
settings are correct, and click the [OK] button.
7
Dynamic
muting
Select Enable or Disable,
measurement time and the
number of allowable beams for
the Dynamic Muting function.
Set the measurement time by
moving the pointer of the bar.
Dynamic muting
Disable
Disable/Enable
Measurement
time
3 s
1 to 25 s (in 0.1 s increments)
Number of
allowable beams
1
0 to 5 beams
(in 1-beam increments)
8
Statistics data
recording
Select Enable or Disable for recording of muting
statistic data.
Enable
Disable/Enable
9
Time
information
setting
Moves to the setting screen of muting time
information.
-
-
10
Override
Set Enable or Disable and time
limit for overriding.
Override
Enable
Disable/Enable
Override input
time limit
1 s
0.1 to 5 s (in 0.1 s increments)
Override time limit 600 s
0 to 600 s
(in 1-s increments)/ (Infinite when 0
is set)
No.
Function
name
Description
Initial value
Configurable value or numerical
range
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...