425
F3SG-SR/PG
User’s Manual
Chapter
8
Troub
le
sho
oting
Appendix
E
* You can check the error codes by SD Manager 3 or SD Manager 3 Mobile APP.
F3SG-SR/PG
LOCKOUT state
X
-
-
The F3SG-SR/PG is in the LOCKOUT state. For details of the
error of the F3SG-SR/PG, check the indicator status or error
code of the F3SG-SR/PG.
Restoration failed
X
-
-
The sensor configuration (sensor model, connection
configuration, etc.) stored in the Intelligent Tap by the Backup
process does not match the sensor configuration of the
connected F3SG-SR/PG. Connect the F3SG-SR/PG with the
same sensor configuration as the backed-up sensor
configuration, or perform the Backup process of the connected
F3SG-SR / PG.
Error codes are not recorded. Refer to
for more information on the Backup and Restoration procedures.
Power supply
voltage error, or
other errors
X
X
A3
The muting inputs A and B are kept in the OFF state when the
LOCKOUT state occurs due to the power supply voltage error.
The power supply voltage may have dropped temporarily when
the F3SG-SR/PG is in operation. Check for temporary power
supply voltage drop (by about 12 VDC) by the influence of the
inductive load, etc.
If the exclusive power supply is not used, check the power
consumption of other connected devices for enough capacity.
Power supply voltage may be outside the rated range.
Connect the F3SG-SR/PG to a 24 VDC±20% power supply
voltage.
Voltage fluctuation may have occurred due to insufficient power
supply capacity.
Replace the power supply with one that has a larger capacity.
Instantaneous break or instantaneous stop may have occurred
due to power sharing with other devices. Do not share the power
supply with other devices.
Connect the F3SG-SR/PG to a power supply that is dedicated to
electro-sensitive protective devices for electro-sensitive
protective equipment such as the F3SG-SR/PG, safety controller,
etc.
DIP Switch circuit
error at startup
X
X
BC
The internal circuit may be defective.
Replace the Intelligent Tap.
IO-Link circuit error
X
X
BD
The internal circuit may be defective.
Replace the Intelligent Tap.
Internal error
X
X
Others
The internal circuit may be defective.
Replace the Intelligent Tap.
Description
Checking by
Error code
(hex)*
Cause and measures
Indicator
SD Manager 3
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...