2-16-2. Factory Default Setting
The Floating Blanking is disabled.
2-16-3. Setting with Intelligent Tap
Floating blanking can be configured using Positions 6 and 7 of the DIP Switch of the Intelligent Tap.
The Floating Blanking Monitoring function is configured as Lockout.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
Refer to
Chapter 3 Setting with Intelligent Tap
for more information on setting this function by the Intelligent Tap.
2-16-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
Setting is required for each sensor segment in case of a cascade connection.
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Setting the Floating Blanking Monitoring function to Disable Monitoring may create an undetectable area where a person
can block the F3SG-SR without being detected, and it is not compliant with IEC 61496-2. Conduct risk assessment
analysis thoroughly before enabling this setting.
Refer to
for more information on changing functions by SD Manager 3.
Function
Initial value
Configurable value or numerical range
Floating Blanking
Disable
Enable/Disable
Floating Blanking Monitoring
Lockout
Disable monitoring/Lockout/Cancel blanking zone
Temporarily Disable Monitoring
Function
Disable
Enable/Disable
Monitoring temporarily disabled
time limit
10 s
1 to 200 s (1-s increments), or infinite
Number of floating beams
1
1 to 15 beams (1-beam increments)
Number of allowable beams
0
0 to 5 beams (1-beam increments)
Summary of Contents for F3SG-PG Series
Page 18: ...xvi Introduction F3SG SR PG User s Manual...
Page 30: ...xxviii Introduction F3SG SR PG User s Manual...
Page 74: ...44 Chapter 1 List of Models F3SG SR PG User s Manual Overview and Specifications...
Page 180: ...150 Chapter 2 IO Link F3SG SR PG User s Manual System Operation and Functions...
Page 438: ...408 Chapter 7 Maintenance Checklists F3SG SR PG User s Manual Checklists...