5. Drive Application Functions
5-44
5.13
Drive Node Address Setting (ADDR)
Set the drive node address. You can verify the set address in the node ID (0x2003). The value of the
node setting switch is read just once when the power is turned on. Any subsequently modified settings
will only take effect when the power is turned off and then turned on again.
As this drive consists of two rotary switches configurable to 0~9 as below, 0~99 node addresses can
be set. The following example shows an address set to 48:
Perform the rotary switch operation for the node ID setting only when drive power is not applied.
0 1
2
3
4
5
6
9
8
7
x10
2
3
4
5
6
9
8
7
x1
0 1
Note: For more information about how the master reads the node address of the EtherCAT drive, refer to 18.4.1
Requesting ID in the document titled "ETG.1020 EtherCAT Protocol Enhancements."