10. Object Dictionary
10-91
0x2610
Drive Rated Current
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
-
-
0.1A
RO
No
-
No
This parameter represents the rated current of the drive.
0x2611
FPGA Version
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
STRING
-
-
-
RO
No
-
No
This parameter represents the version of FPGA within the drive.
0x2612
Hall Signal Display
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
-
-
-
RO
No
-
No
This parameter represents the signal of the hall sensor installed in the encoder (or motor). You can
use this to verify the connection status of the hall sensor signal or compare the U/V/W phases of
the motor with the direction of the hall sensor signal.
The signal value is repeated in the order of 5
4
6
2
3
1 for a positive movement, and it is
repeated in the order of 1
3
2
6
4
5 for a negative movement.
Bits
Setting details
0
W phase hall sensor signal
1
V phase hall sensor signal
2
U phase hall sensor signal
0x2613
Bootloader Version
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
STRING
-
-
-
RO
No
-
No
This parameter represents the bootloader version of the drive.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......