10. Object Dictionary
10-55
0x2111
External Positive Torque Limit Value
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 5000
3000
0.1%
RW
Yes
Always
Yes
You can set the external positive torque limit value according to the torque limit function select
(0x2110).
0x2112
External Negative Torque Limit Value
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 5000
3000
0.1%
RW
Yes
Always
Yes
You can set the external negative torque limit value according to the torque limit function select
(0x2110).
0x2113
Emergency Stop Torque
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 5000
1000
0.1%
RW
Yes
Always
Yes
You can set torque stop during emergency stop (POT, NOT, ESTOP input).