10. Object Dictionary
10-59
0x211B
Gain Conversion Time 2
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
2
ms
RW
Yes
Always
Yes
This specifies the time to switch from gain group 2 to gain group 1.
0x211C
Gain Conversion Waiting Time 1
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
0
ms
RW
Yes
Always
Yes
This specifies the waiting time before switching from gain group 1 to gain group 2.
0x211D
Gain Conversion Waiting Time 2
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
0
ms
RW
Yes
Always
Yes
This specifies the waiting time before switching from gain group 2 to gain group 1.
0x211E
Dead Band for Position Control
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
0
UU
RW
Yes
Always
Yes
The position controller output is 0 if the following error for position control is below the setting.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......