10. Object Dictionary
10-89
0x2608
Mechanical Angle
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
-
-
0.1deg
RO
Yes
-
No
This parameter represents the single-turn data of the motor in the range of 0.0~359.9.
0x2609
Electrical Angle
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
-
-
0.1deg
RO
Yes
-
No
This parameter represents the electrical angle of the motor in the range of -180.0~180.0.
0x260A
MultiTurn Data
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
DINT
-
-
rev.
RO
Yes
-
No
This parameter represents multi-turn data of the multi-turn encoder.
0x260B
Drive Temperature 1
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
-
-
o
C
RO
No
-
No
This is the temperature measured by the temperature sensor integrated into the drive power board.
If the measurement is higher 95
℃
or higher, a drive overheat alarm 1 (AL-22) is generated.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......