9. Full-Closed Control
9-8
0x2028
External Encoder Following Error Reset
ALL
Variable
Type
Setting Range
Initial
Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UDINT
0 to 10000
10
Revolution
RW
No
Power
cycling
Yes
This sets the position error level for the external encoder and the reset range for the error position
value.
Based on the 0x2027 (External Encoder Following Error Window) settings, the AL-54 (Encoder2 POS
difference) level can be adjusted.
For a system where a slip occurs, the 0x2028 (External Encoder Following Error Reset) settings can be
used to set the normal slip range for the following error value.
G. Setting the dual-feedback filter time constant
0x2024
Dual Feedback Conversion Time Constant
ALL
Variable
Type
Setting Range
Initial
Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
0
0.1ms
RW
No
Always
Yes
In the case of dual-feedback control that refers to an external encoder, the filter time constant is set to
0.1 ms at the time when the mode switches between semi-closed control and full-closed control.
As the setting value gets close to 0 ms, it refers to the external encoder more. As it gets close to 100
ms, it refers to the motor-side encoder more. It minimizes the vibrations that are generated due to
mechanical characteristics or external factors to shorten the adjustment time.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......