5. Drive Application Functions
5-30
`
Servo ON/
OFF
PWM
output
Servo OFF or
alarm occurred
PWM OFF delay time
(0x2011)
Time when the
PWM output
is turned off
Brake
Signal
Direction
of Gravity
Motor
Load
(1) When the brake signal is output before PWM output is turned off
You can output the brake signal first before PWM output is turned off to prevent the drop along the
vertical axis due to gravity.
PWM OFF delay time
(0x2011)
`
Servo ON/
OFF
PWM
output
Servo OFF or
alarm occurred
Time when the
PWM output
is turned off
Brake
Signal
Direction
of Gravity
Motor
Load
(2) If PWM output is turned off before the brake signal output
PWM output is turned off before the brake signal output, allowing the drop along the vertical axis due to
gravity.