9. Full-Closed Control
9-3
9.2
Full-Closed Control Parameter Settings
You can set the full-closed control parameters in the following order.
A. Setting the full-closed control mode
0x2023
Full-Closed Control Mode
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 2
0
-
RW
No
Power
cycling
Yes
This sets the full-closed control mode.
Setting
value
Setting details
0
Semi-Closed Control (controls using only the motor-side encoder, default value)
1
Full-Closed Control (controls using the load-side position sensor)
2
Dual-Feedback Control (controls using the motor-side encoder and load-side
position sensor)
B. Setting the load encoder-type
0x2021
Load Encoder Type
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1
0
-
RW
No
Power
cycling
Yes
This sets the second encoder type on the load side.
Setting value
Setting details
0
Incremental encoder: Pulse type incremental encoder
1
SSI encoder: Serial communication type incremental encoder
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......