10. Object Dictionary
10-66
0x2221
Analog Monitor Channel 1 Select
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 65535
0
-
RW
No
Always
Yes
This sets the monitoring variables to be output to analog monitor output channel 1.
Setting Value
Displayed Items
Unit
0x00
Speed feedback
rpm
0x01
Speed command
rpm
0x02
Speed error
rpm
0x03
Torque feedback
%
0x04
Torque command
%
0x05
Following error
pulse
0x06
Accumulated operation overload
%
0x07
DC link voltage
V
0x08
Accumulated regeneration overload
%
0x09
Encoder single-turn data
pulse
0x0A
Inertia ratio
%
0x0B
Full-Closed Positional Error
UU
0x0C
Drive temperature 1
°C
0x0D
Drive temperature 2
°C
0x0E
Encoder temperature 1
°C
0x0F
Hall signal
-
0x10
U phase current
A
0x11
V phase current
A
0x12
W phase current
A
Setting Value
Displayed Items
Unit
0x13
Current position value
UU
0x14
Target position value
UU
0x15
Position command speed
rpm, mm/s
0x16
Hall U signal
-
0x17
Hall V signal
-
0x18
Hall W signal
-
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......