10. Object Dictionary
10-87
Monitoring (0x2600~ )
0x2600
Feedback Speed
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
-
-
rpm
RO
Yes
-
No
This parameter represents the current rotation velocity of the motor.
0x2601
Command Speed
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
-
-
rpm
RO
Yes
-
No
This parameter represents the speed command input to the velocity control loop of the drive.
0x2602
Following Error
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
DINT
-
-
pulse
RO
Yes
-
No
This parameter represents the following error of position control.
0x2603
Accumulated Operation Overload
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
-
-
0.1%
RO
No
-
No
This parameter represents the accumulated operation overload rate. When the accumulated
operation overload rate reaches the overload warning level (0x2010), an operation overload
warning (W10) occurs; when it reaches 100%, an operation overload alarm (AL-21) occurs.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......