10. Object Dictionary
10-75
0x2403
INPOS2 Output Range
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 60000
100
UU
RW
Yes
Always
Yes
This parameter outputs the INPOS2 signal when the following error is lower than the setting value.
Unlike INPOS1, the INPOS2 signal is output by calculating only the following error value.
0x2404
ZSPD Output Range
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 6000
10
rpm
RW
Yes
Always
Yes
When the current velocity is lower than the setting value, the parameter outputs the ZSPD signal.
0x2405
TGON Output Range
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 6000
100
rpm
RW
Yes
Always
Yes
When the current velocity is higher than the setting value, the parameter outputs the TGON signal.
0x2406
INSPD Output Range
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 6000
100
rpm
RW
Yes
Always
Yes
When the velocity error is lower than the setting value, the parameter outputs the INSPD signal.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......