10. Object Dictionary
10-90
0x260C
Drive Temperature 2
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
-
-
o
C
RO
No
-
No
This parameter represents the temperature measured by the temperature sensor integrated into
the drive control board. If the measured temperature is 90
℃
or higher, a drive overheat alarm 2
(AL-25) is generated.
0x260D
Encoder Temperature
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
-
-
o
C
RO
No
-
No
This parameter represents the temperature measured by the temperature sensor integrated into
the serial encoder provided by our company (if the setting value of the encoder type (0x2001) are 3,
4, 5, and 6). If the measured temperature 90
℃
or higher, an encoder overheat alarm (AL-26) is
generated.
0x260E
Motor Rated Speed
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
-
-
rpm
RO
No
-
No
This parameter represents the rated speed of a driving motor.
0x260F
Motor Maximum Speed
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
-
-
rpm
RO
No
-
No
This parameter represents the maximum velocity of a driving motor.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......