10. Object Dictionary
10-74
Miscellaneos Setting(0x2400~ )
0x2400
Software Position Limit Function Select
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 3
0
-
RW
No
Always
Yes
You can set the software position limit function for position control. When you use the position limit
function, the upper and the lower limits in (0x607D:02) and (0x607D:01) are used. The software
position limit function will not be activated prior to the homing operation. In addition, when the upper
limit value is less than the lower limit value, this function will not be activated.
Setting Value
Setting details
0
None of the positive and negative direction software position limits
are used
1
Only the positive direction software position limit value is used It is
not limited for the negative direction
2
Only the negative direction software position limit value is used It is
not limited for the positive direction
3
Both the positive and the negative direction software position limits
are used
0x2401
INPOS1 Output Range
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 60000
100
UU
RW
Yes
Always
Yes
With the position command not newly updated, if the following error is retained within the INPOS1
output range for the INPOS1 output time, the INPOS1 signal is output.
0x2402
INPOS1 Output Time
P
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
0
ms
RW
Yes
Always
Yes
Refer to the description of 0x2401.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......