5. Drive Application Functions
5-11
Related Objects
Index
Sub
Index
Name
Variable
Type
Accessibility
PDO
Assignment
Unit
0x2220
-
Analog Monitor Output Mode
UINT
RW
No
-
0x2221
-
Analog Monitor Channel 1 Select
UINT
RW
No
-
0x2222
-
Analog Monitor Channel 2 Select
UINT
RW
No
-
0x2223
-
Analog Monitor Channel 1 Offset
DINT
RW
No
-
0x2224
-
Analog Monitor Channel 2 Offset
DINT
RW
No
-
0x2225
-
Analog Monitor Channel 1 Scale
UDINT
RW
No
-
0x2226
-
Analog Monitor Channel 2 Scale
UDINT
RW
No
-
Analog monitor output mode settings (0x2220)
The output range of the analog monitor is from -10 V to +10 V. If the setting is 1, take the absolute
value of the output so the output values is only positive.
Settings
Details
Description
0
1
Output only positive
values
+10V
0V
-10V
+10V
0V
Analog
Output Voltage
Analog
Output Voltage
Output as negative/
positive values