10. Object Dictionary
10-108
0x605A
Quick Stop Option Code
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
0 to 4
2
-
RW
No
Always
Yes
This sets the quick stop option code.
Setting Value
Description
0
Not used (transits into Switch On Disabled).
1
Slowly decelerates and stops according to the quick stop
deceleration (0x6085) setting. (Switch On Disabled).
2
Slowly decelerates and stops according to the quick stop
deceleration (0x6085) setting. (Switch On Disabled).
3
Stops using the torque limit value (Switch On Disabled)
0x605B
Shutdown Option Code
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
0 to 1
0
-
RW
No
Always
Yes
This sets the operation to shut down the servo drive (Operation Enabled state -> Ready to Switch
On state).
Setting Value
Description
0
Not used
1
Decelerates to a stop; enters the Switch On Disabled state; enters
the Ready state
0x605C
Disable Operation Option Code
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
INT
0 to 1
1
-
RW
No
Always
Yes
This sets the Disable Operation state (Operation Enabled state
Switched On state) option code.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......