10. Object Dictionary
10-98
Third Party Motor Support(0x2800~ )
The following motor parameters are provided for driving motors manufactured by a third party in
addition to our motor. To drive a third party's motor with our drive, you have to enter correct
parameters. In this case, however, our company neither has performed any test for combinations of
our drive and a third party motor nor provides any warranty for the motors’ characteristics.
0x2800
[Third Party Motor] Type
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1
0
-
RW
No
Power
cycling
Yes
You can set the motor type.
Setting Value
Setting details
0
Rotary motor
1
Linear motor
0x2801
[Third Party Motor] Number of Poles
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
2 to 1000
8
-
RW
No
Power
cycling
Yes
You can set the number of motor poles. For a linear motor, set the value to 2.
0x2802
[Third Party Motor] Rated Current
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
FP32
-
2.89
Arms
RW
No
Power
cycling
Yes
You can set the rated current of the motor.
0x2803
[Third Party Motor] Maximum Current
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
Variable
Attribute
Savin
g
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......