2. Wiring and Connection
2-21
2.5.2
Names and Functions of Analog Input/Output
Signals
Names and Functions of Analog Output Signals (Analog Monitoring
Connector)
Pin
Number
Name
Details
Function
1
AMON1
Analog Monitor 1
Analog Monitor output (AT NC Axis in case of -
10V~+10V signal
신호면
AT NC Axis 10)
2
AMON2
Analog Monitor 2
Analog Monitor output (AT NC Axis in case of -
10V~+10V signal
신호면
AT NC Axis 10)
3
AGND
AGND(0V)
Analog ground
4
AGND
AGND(0V)
Analog ground
Note 1) You can change the output variables to be monitored with analog monitor output through parameter
settings.
For more information, refer to Section 5.2.3 “Assignment of Analog Output Signals.”