10. Object Dictionary
10-85
0x2515
Vibration Supression Filter Configuration
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 2
0
-
RW
No
Always
Yes
Set whether to use a filter to suppress vibration generated at the load end.
Setting Value
Setting details
0
Vibration suppression (damping) filter is not used.
1
Vibration suppression (damping) filters 1 and 2 are used.
2
Vibration suppression (damping) filters 1 and 2 are used according
to LVSF1 and LVSF2 inputs.
0x2516
Vibration Supression Filter 1 Frequency
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
0
0.1Hz
RW
No
Always
Yes
Set the vibration suppression (damping) filter 1 frequency.
0x2517
Vibration Supression Filter 1 Damping
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 5
0
-
RW
No
Always
Yes
Set the coefficient of vibration suppression (damping) filter 1. The larger the set value, the bigger
the damping coefficient becomes, leading to a higher damping level.
0x2518
Vibration Supression Filter 2 Frequency
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1000
0
0.1Hz
RW
No
Always
Yes
Set the vibration suppression (damping) filter 2 frequency.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......