5. Drive Application Functions
5-35
Waiting time and switching time for gain conversion are as follows.
Gain Group 1
Gain Conversion Time 1
(0x211A)
Gain Conversion Waiting Time 1
(0x211C)
Gain Conversion Time 2
(0x211B)
Gain Conversion Waiting Time 2
(0x211D)
Gain Group 2
Position Loop Gain 1 (0x2101)
Speed Loop Gain 1 (0x2102)
Speed Loop Integral Time Constant 1
(x2103)
Torque Command Filter Time Constant
1 (0x2104)
Position Loop Gain 2 (0x2105)
Speed Loop Gain 2 (0x2106)
Speed Loop Integral Time Constant 2
(x2107)
Torque Command Filter Time
Constant 2 (0x2108)
시간
Gain Group 2
Gain Group 1
Gain Group 1
Gain switching condition is met
(ex. GAIN2, ZSPD, INPOS1)
Gain switching condition
is not met
Dwell Time 1
0x211C
Switching
Time 1
0x211A
Dwell Time 2
0x211D
Dwell Time 2
0x211B
Related Objects
Index
Sub
Index
Name
Variable
Type
Accessibility
PDO
Assignment
Unit
0x2119
-
Gain Conversion Mode
UINT
RW
Yes
-
0x211A
-
Gain Conversion Time 1
UINT
RW
Yes
ms
0x211B
-
Gain Conversion Time 2
UINT
RW
Yes
ms
0x211C
-
Gain Conversion Waiting Time 1
UINT
RW
Yes
ms
0x211D
-
Gain Conversion Waiting Time 2
UINT
RW
Yes
ms
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......