9. Full-Closed Control
9-9
Example of setting the dual-feedback filter time constant
H. Setting the dual-feedback filter time constant
0x2029
Load Feedback Type
ALL
Variable
Type
Setting Range
Initial
Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 1
0
-
RW
No
Power
cycling
Yes
This setting determines that you can select linear type or rotary type in the load encoder type.
0 : Rotary / 1 : Linear
Time
Remaining
pulse
Command
Pulse
Time
Remaining
pulse
Command
Pulse
Shortens the time for position adjustment
Weighted value of semi-closed control
increases.
Increase the size of the dual feedback filter.
Weighted value of the motor-side encoder
increases.
Decrease the size of the dual feedback filter.
Weighted value of the load-side encoder
increases.
Vibrations suppressed
Weighted value of full-closed control increases.
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......