4. CiA402 Drive Profile
4-25
-6
The drive returns to the home position only with the home switch (HOME) while driving in the
positive direction.
Related Objects
Index
Sub
Index
Name
Variable
Type
Accessibility
PDO
Assignment
Unit
0x6040
-
Controlword
UNIT
RW
Yes
-
0x6041
-
Statusword
UINT
RO
Yes
-
0x607C
-
Home Offset
DINT
RW
No
UU
0x6098
-
Homing Method
SINT
RW
Yes
-
0x6099
-
Homing Speed
-
-
-
-
0
Number of entries
USINT
RO
No
-
1
Speed during search for switch
UDINT
RW
Yes
UU/s
2
Speed during search for zero
UDINT
RW
Yes
UU/s
0x609A
-
Homing Acceleration
UDINT
RW
Yes
UU/s
2