12. Maintenance and Inspection
12-16
Servo Drive Overload Graph (2kW, 3.5kW)
Load Factor
(%)
AL-21 duration (sec)
Load Factor
(%)
AL-21 duration (sec)
Turn
Stop
Turn
Stop
100 or lower
Infinite
Infinite
110
4832
4832
210
66.8
44
120
1208
1208
220
50.1
36
130
536
536
230
38.5
30.3
140
302
302
240
30.3
9.7
150
257
154
250
24.2
8.3
160
229
100
260
4.2
3.8
170
200
85
270
3.8
3.4
180
165
70
280
3.4
3.1
190
131
61
290
3.0
2.7
200
103
52
300
2.7
2.5
Time
(Sec)
Overload(%)