10. Object Dictionary
10-38
0x2018
Magnetic Pole Pitch
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
1 to 65535
2400
.01mm
RW
No
Power
cycling
Yes
You can set the pitch between the magnetic poles of the linear motor. Pole pitch refers to the
distance between the north poles or the south poles of magnets, which corresponds to an electrical
angle of 360˚.
0x2019
Linear Scale Resolution
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
1 to 65535
1000
nm
RW
No
Power
cycling
Yes
You can set linear scale resolution in the unit of nm. For a linear scale with a resolution of 1um, set
it to 1000 (= 1um/1nm).
0x201A
Commutation Method
ALL
Variable
Type
Setting Range
Initial Value
Unit
Accessi
bility
PDO
Assignm
ent
Variable
Attribute
Savin
g
UINT
0 to 2
0
-
RW
No
Power
cycling
Yes
This specifies the commutation method to get information on the initial angle of the motor.
Setting
Value
Description
0
Separate commutation is unnecessary or it carries out commutation using a
hall sensor
1
Carries out commutation when the servo is turned on for the first time
2
Reserved
Summary of Contents for L7NHF Series
Page 2: ......
Page 14: ...Table of Contents xii ...
Page 60: ...2 Wiring and Connection 2 38 ...
Page 158: ...6 Safety Functions 6 6 ...
Page 172: ...7 Tuning 7 14 ...
Page 182: ...8 Procedure Function 8 10 ...
Page 192: ...9 Full Closed Control 9 10 ...
Page 214: ...10 Object Dictionary 10 22 ...
Page 363: ...11 Product Specifications 11 43 ...
Page 364: ......