iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
498
4.4.9.2
LCR LDT (Leading Digit Table) - PGM 221
Selecting LCR-LDT (Leading Digit Table) will display the LCR-LDT data entry page. Select the LDT Index
range desired, blue text above the table header.Click
[Save]
button after changing Value.
Enter LDT Table Index Range: eMG80/100: 1-10 / eMG800: 1-32 / UCP: 1-32
Figure 4.4.9.2-1 LCRLeading Digit Table
The Leading Digits Table is used to analyze the user-dialed digits to determine an appropriate Digit
Modification Table Index.
LDT Tables are provided for 10 for eMG80/100 system& 32 for eMG800/UCP system. The Table is divided into
bins. The applicable LCR Access Modes (LCR Type) and the digits (up to the first 12) dialed by the user are
compared with the entries in the Leading Digit Table.
In addition, indices to the Digit Modification Table are defined for each of the three (3) Zones and Time Zones
configured in the LCR Control Attributes. The following table provides a brief description and entries for the
Leading Digit Table.
Table 4.4.9.2-1 LCR LEADING DIGITS
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
LCR Type
This entry defines the LCR modes that will apply to this
LDT index.
Internal,
CO Line,
Both
Both
Compared Digits
Up to 12 digits that, if matched by the user dialed digits,
will access the DMT Indices of the associated Leading
Digit Table bin.
Max. 12 digits
(Include * and #)
Check Password
If enabled (ON), when the dialed digits match the LDT
digits, the system will send second dial tone to request
the user input a valid Authorization code.
OFF
ON
OFF
LDT Zone Number
If the LDT Zone Number of a station/co line is equal to
this value, this LDT table is available to the station/co
line.
1-100
1