277
Table 4.4.2.3-1Terminal Attributes
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
SLT Open Loop
Time
Send open loop signal to SLT port when counter party user
hangs up SLT.
0~9
(100ms)
0
Short Modem
If this value of a SLT is ON, the SLT is the modem mode in
seizing a CO line.When the CO line is CO board, the {short
modem timer} is starting when the SLT seizes the co line. And if
the {short modem timer} is expired, the SLT go to the original
mode.When the CO line is ISDN, the {short modem timer} is
starting after receiving the ISDN connect message. And if the
{short modem timer} is expired, the SLT go to the original mode.
OFF
ON
OFF
Line Echo
When LKA-200 SLT is used, the echo may be hearing. If this
option is set to ON, the echo won
’t be happen.
OFF
ON