Table 3.3.8.7-1 Prefix Dialing Table (PGM 206)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
6
001 NUM PLAN(0-6)
UNKNOWN(0)
Select Numbering Plan (0~6).
0:Unknonw
1:ISDN/Telephony
2:Data numbering
3:Telex
4:National standard
5:Private
6:Reserved
Refer to
description
0
7
001 SENDING COMPLETE
(1:ON/0:OFF) : OFF
Select Sending Complete option. (On/Off)
0-1
OFF
8
001 CALL TYPE (0-5)
UNKNOWN(0)
Call Charge Type (0~5).
0:Unknown
1:Local
2:Long Distance
3:International
4:Mobile
5:reserved
Refer to
description
0
9
001 CALL TIMER(sec)
(000
– 999) : 000
Call Charge Timer can be assigned. By this
timer value Call Metering can be established.
000-999
000
10
001 CALL COST
000000
Call Cost is calculated by CALL TIMER. (ex :
timer is 1 min, cost is 000020, then after 3
minute call, total call cost is calculated to
000060)
000000-
999999
000000
11
001 FLAT RATE
(1:ON/0:OFF) : OFF
If Flat Rate is ON, Flat Rate is applied by
CALL COST per a call
0-1
OFF
12
PREFIX TABLE INIT
PRESS [HOLD] TO INIT
Initialize Prefix table.