iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
96
3.3.5.10 T1 Line Timers
– PGM 152
North American T1 standards require that the T1 terminating device, in this case the iPECS eMG, include
various “adjustable” timers and counters as described below.
PROCEDURE
COL T1 ATT
ENTER CO RANGE
Press the
[PGM]
button and dial 152.
01-02 COL T1 ATT
PRESS FLEX KEY (01-13)
Use the dial-pad to enter a CO Line range (Ex. 01-02). For a single CO Line,
enter the same number twice.
Press the desired Flex button; refer to Table 3.3.5.10-1.
Use the dial-pad to enter desired data for the Attribute, refer to Table
3.3.5.10-1.
Press the
[Save]
button to store the data entry.
Table 3.3.5.10-1 T1 LINE TIMERS (PGM 152)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
1
01-02 PAUSE
(1-9) : 2 (sec)
A timed pause may be included in a Speed
Dial number, in which case, the pause time is
defined by this entry.Not currently
implemented.
1~9
(seconds)
2
2
01-02 RLS GRD
(01-60) : 20 (100ms)
The releaseguard timer defines the length of
time the system will maintain a Line as busy
after the call has been terminated to assure
the PSTN has sufficient time to ‘clear down’
the circuit. Not currently implemented.
01~60
(100 ms)
20
3
01-02 DT DELAY
(02-50) : 10 (100ms)
The DT (Dial tone) Delay timer defines the
duration that dial tone must be received for
DT recognition.
Not currently implemented.
02~50
(100 ms)
10
4
01-02 INTER DGT
(15-30) : 15 (20ms)
The Inter Digit timer defines the duration
between digit transmissions.
Not currently implemented.
15~30
(20 ms)
15
5
01-02 WINK
(07-15) : 10 (20ms)
For TIE or DID Lines the Wink timer defines
the length of time the ‘wink’ (T1 TIE line
circuit reversal) will last.
7~15
(20 ms)
10
6
01-02 OP RATE ( 0- 3)
60-40 (10pps) (0)
For Pulse signaling, defines the duration and
make/break ratio of each pulse.
0: 60-40(10pps), 1: 66-33(10pps)
2: 60-40(20pps), 3: 66-33(20pps)
Refer to
description
60-40
(10pps)
7
01-02 SEZ DTC
(000-127) : 003 (20ms)
This timer defines the length of a valid ‘line
seizure’ signal.
0~127
(20 ms)
3