4.4.14.1 Remote Device Registration
– PGM 442
Selecting the Remote Device Registration will display the Remote Registration Table data input page. Enter a
Table index range and select
[Load]
to enter MAC address information. For convenience, the copy, paste, and
drag is available to enter or modify data.Click
[Save]
button after changing Value.
Figure 4.4.14.1-1 Remote Device Registration
When a device attempts to register with the controlling iPECS, the system will check the device MAC address
and password against the Registration table. If a match is found, the device is registered regardless of Dip-
switch 2 position of eMG and Dip Switch position 3 of UCP. The system database is updated and the device
receives device specific configuration data from the MPB/UCP.
Table 4.4.14.1-1 REMOTE DEVICE REGISTRATION
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Mac Address
Mac address of remote device
MAC Address
Password
Password, if any, assigned in the devices database via
Device Web admin.
Up to 12 digits
Zone
The Zone to be assigned to the device.
01-32
01
Nation code
Nation or country location of the device.
Assigned in
System ID