iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
176
Table 3.3.9.1.1-1 LCR CONTROL ATTRIBUTES (PGM 220)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE
DEFAULT
2
DAY ZN 1:1234567 2: 3:
M1 T2 W3 T4 F5 SA6 SU7
For each day of the week, a Day Zone (1
to 3) is assigned. The active Day Zone is
the Zone assigned to the current day of
the week (Flex button 1~7).
Flex 1~7 +
1~3
Zone 1: all
days of
the week
3
TIME ZONE 1
1:00-24 2: . .-. . 3:. .- . .
This entry defines the hours of the day
during which Time Zone 1 is active. Note
hours not defined in Time Zone 2 and 3
are automatically part of Time Zone 1.
00~24
00~24
4
TIME ZONE 2
1:00-24 2: . .-. . 3:. .- . .
This entry defines the hours of the day
during which Time Zone 2 is active.
00~24
00~24
5
TIME ZONE 3
1:00-24 2: . .-. . 3:. .- . .
This entry defines the hours of the day
during which Time Zone 3 is active.
00~24
00~24