Table 4.4.13.6-1 ZONE ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Remark
Descriptive information to help installer/programmer in
identifying the device Zone, i.e. Branch1.
Max. 21
characters
Display time zone
The time & date displayed at the station are based on the
time zone selected or the system time
Time zone, System time
Refer to
description
System
time
Max Total Inter
Zone Connections
This parameter may be used to limit the number of
maximum Inter Zone connections. When this value is set to
0, there is no limit on the total Inter Zone connections.
eMG80/100:0-140, eMG800: 0-1200, UCP: 0-2400 (0: No
limit)
Refer to
description
0
Max Outgoing CO
Calls
This field may be used to limit the number of outgoing
CO/IP calls from the Zone. When this value is set to 0,
there is no limit on the number of outgoing CO/IP calls.
eMG80/100:0-74, eMG800: 0-600, UCP: 0-998 (0: No limit)
Refer to
description
0
Zone MOH Assign
A Music source can be assigned so that calls to this zone.
Refer to Sys Hold,Internal music, External Music,
VSFMOH,SLT MOH1~5,VSF MOH2~30
Refer to
description
Refer to
Sys Hold
Emergency Call
Notify Station
Assigns the destination station for Emergency Call
Notification.
Station
number
Emergency Call
Notify 2nd Station
This field assigns a secondary station to receive notification
of an Emergency call from a device in the Zone.
Station
number
DCOB Fault Notify
Station
This field assigns the station to receive notification of a
DCOB (Digital CO Board) fault.
Station
number
SIP Registration
Fault Notify Station
This field assigns the station to receive notification of a SIP
Trunk registration fault.
Station
number
Daylight Saving
Usage
If option is "System DST mode", the zone will follow the
system DST mode(System Date&Time(178)).If option is
"OFF", the zone will not apply the Daylight Saving Time.
System DST mode, OFF
Refer to
description
System
DST mode