Table 4.4.4.4-1 ISDN ATTRIBUTES
ATTRIBUTE
DESCRIPTION
RANGE
DEFAULT
Screening
indicator
The ISDN Screening Indicator can be configured.
User Provided, No Service
User Provided, Pass
User Provided, Fail
Network Provided.
Refer to
description
User
Provided, No
Service
ISDN PLUS
Code
When the incoming CLI starts
with “+”, this value will be
inserted in place of the
“+” sign.
0000-9999
-
CP/Alert inband
Send progress indication with in-band information in Call
proceeding and Alerting messages.
OFF
ON
OFF
Disconnect
inband
Send progress indication with in-band information in
Disconnect message.
OFF
ON
OFF
Disconnect with
Inband Info
When system receives DISCONNECT message with Inband
information from PSTN, the following option can be applied:
Ignore Inband information:
Line is disconnected
Bypass Inband information:
Progress Information is
transferred
Wait Release:
System wait to send Release message till
the other party is disconnected
Refer to
description
Wait Release