iPECS eMG80/100& eMG800 & UCP & vUCP
Administration and Programming Manual
Issue 2.3
205
3.3.11 TNET (Centralized Networking)
–
PGM 330 ~ 336
In a Centralized Control TNET (Transparent Networking), remote devices may be registered to a Central
MPB/MPB (CM) and to a Local MPB/MPB (LM).
In this way, the CM maintains control of the remote device. Should the WAN connection between an LM and
CM fail (2 second polling error), the LM will initiate operational control of the locally registered devices.
Calls between the systems (CM & LM) can automatically shift to PSTN Modules registered with the LM for
Fail-over operation. The configuration and characteristics of LMs and CM are configurable as is Fail-over
operation.
3.3.11.1 TNET Basic Attributes
– PGM 330
Each MPB in a Central Control network environment must be enabled for TNET operation in order to function
as part of the network.
PROCEDURE:
TNET BASIC ATTRIBUTES
PRESS FLEX KEY (1
– 1)
Press the
[PGM]
button and dial 330.
TNET ENABLE
(1:ON/0:OFF) : OFF
Press Flex button 1.
Use the dial-pad to enable or disable TNET, Central Control networking.
Press the
[Save]
button to store the new data.
3.3.11.2 TNET CM Attributes
– PGM 331
Each LM (Local MPB), which is part of a Central Control Network, must be defined with the IP Address of the
CM (Central MPB) as well as the LM configuration data that will be sent to the CM at the time the LM registers
with the CM.
The port counts define the ports, which are allocated in the CM database for use by devices registered to the
LM. The number of ports defined in the database of each LM must be equal or less than the ports defined in
the CM for the LM, see PGM 332, in order to register properly.
PROCEDURE:
TNET CM ATTRIBUTES
PRESS FLEX KEY (1
– 10 )
Press the
[PGM]
button and dial 331.
Press the Flex button, 1~6 for the desired setting, refer to Table 3.3.11.2-1.
Use the dial-pad to enter the required data, refer to Table 3.3.11.2-1.
Press the
[Save]
button to store the new data.
Table 3.3.11.2-1 TNET CM ATTRIBUTES (PGM 331)
BTN
ATTRIBUTE/DISPLAY
DESCRIPTION
RANGE DEFAULT
1
CM REGISTER REQ
(1:ON/0:OFF) : ON
This field informs the LM to attempt registration
with the CM. This field must be set to ON for
proper registration.
0: OFF
1: ON
OFF