W.3048006 [W.3048006] UEFI has booted from the backup flash bank due to an Automatic Boot
Recovery (ABR) event.
Explanation:
Automated Boot Recovery, Booting Backup UEFI Image
Severity
Warning
User Response
Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2. Update the primary UEFI image.
3.
Replace the system board.
Related links
–
“Updating firmware and device drivers” on page 21
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
W.305000A [W.305000A] An invalid date and time have been detected.
Explanation:
RTC Date and Time Incorrect
Severity
Warning
User Response
Complete the following steps:
1. Check IMM/chassis event log. This event should immediately precede 0068002 error. Resolve
that event or any other battery related errors.
2. Use F1 Setup to reset date and time. If problem returns after a system reset, replace CMOS
battery.
3. If problem persists then check the IBM support site for an applicable service bulletin or firmware
update that applies to this error.
4.
Replace the system board.
Related links
–
“Removing the CMOS battery” on page 650
–
“Installing the CMOS battery” on page 651
–
“Updating firmware and device drivers” on page 21
–
“Using the Setup utility” on page 24
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
W.3058009 [W.3058009] DRIVER HEALTH PROTOCOL: Missing Configuraiton. Requires Change
Settings From F1.
Explanation:
DRIVER HEALTH PROTOCOL: Missing Configuration. Requires Change Settings From F1
606
Flex System x220 Compute Node Installation and Service Guide
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...