c. If device is not recognized, reconfiguring slot to Gen1 or Gen2 may be required. Gen1/Gen2
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports -> PCIe
Gen1/Gen2/Gen3 Speed Selection, or the ASU Utility.
2. Check the IBM support site for an applicable device driver, firmware update, or other information
that applies to this error. Load the new device driver and install any required firmware updates.
3. If the problem persists, remove the adapter. If the system reboots successfully without the
adapter, replace that adapter.
4.
Replace the processor.
Related links
–
“Removing an I/O expansion adapter” on page 666
–
“Installing an I/O expansion adapter” on page 667
–
“Using the Setup utility” on page 24
–
“Updating firmware and device drivers” on page 21
–
“Removing a microprocessor and heat sink” on page 675
–
“Installing a microprocessor and heat sink” on page 678
•
S.3020007 [S.3020007] A firmware fault has been detected in the UEFI image.
Explanation:
Internal UEFI Firmware Fault Detected, System halted
Severity
Error
User Response
Complete the following steps:
1. Check the IBM support site for an applicable service bulletin or firmware update that applies to
this error.
2.
Update the UEFI image.
3.
Replace the system board.
Related links
–
“Updating firmware and device drivers” on page 21
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
S.3028002 [S.3028002] Boot permission timeout detected.
Explanation:
Boot Permission Negotiation Timeout
Severity
Error
User Response
Complete the following steps:
1. Check CMM/IMM logs for communication errors and resolve.
2.
Reseat the system.
3. If problem persists, contact Support.
597
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...