Severity
Warning
User Response
Complete the following steps:
1. Go to the Setup Utility (System Settings -> Settings -> Driver Health Status List) and find a
driver/controller reporting Configuration Required status.
2. Search for the driver menu from System Settings and change settings appropriately.
3. Save settings and restart system.
Related links
–
“Using the Setup utility” on page 24
•
W.305800A [W.305800A] DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller.
Explanation:
DRIVER HEALTH PROTOCOL: Reports 'Failed' Status Controller
Severity
Warning
User Response
Complete the following steps:
1.
Reboot the system.
2. If problem persists, switch to backup UEFI or update the current UEFI image.
3.
Replace the system board.
Related links
–
“Updating firmware and device drivers” on page 21
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
•
W.305800B [W.305800B] DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller.
Explanation:
DRIVER HEALTH PROTOCOL: Reports 'Reboot' Required Controller
Severity
Warning
User Response
Complete the following steps:
1. No action required. The system will reboot at the end of POST.
2. If the problem persists, switch to the backup UEFI image or update the current UEFI image.
3.
Replace the system board.
Related links
–
“Updating firmware and device drivers” on page 21
–
“Removing the system-board assembly” on page 683
–
“Installing the system-board assembly” on page 684
607
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...