Step 5.
Touch the static-protective package that contains the DIMM to any
unpainted
metal surface on
the Flex System chassis or any
unpainted
metal surface on any other grounded rack component
in the rack in which you are installing the DIMM for at least 2 seconds; then, remove the DIMM
from its package.
Step 6.
Make sure that both retaining clips on the DIMM connector are in the open position.
Step 7.
Turn the DIMM so that the DIMM keys align correctly with the DIMM connector on the system board.
Attention:
To avoid breaking the retaining clips or damaging the DIMM connector, handle the
clips gently.
Step 8.
Press the DIMM into the DIMM connector. The retaining clips lock the DIMM into the connector.
Step 9.
Make sure that the small tabs on the retaining clips engage the notches on the DIMM. If there is a
gap between the DIMM and the retaining clips, the DIMM has not been correctly installed. Press
the DIMM firmly into the connector, and then press the retaining clips toward the DIMM until
the tabs are fully seated. When the DIMM is correctly installed, the retaining clips are parallel
to the sides of the DIMM.
000
000
000
000
000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
0000000000
Right
air baffle
Left
air baffle
Step 10. Install the air baffle over the DIMM connector.
Attention:
To maintain proper system cooling, ensure correct placement of the air baffles. Do not
operate the compute node without air baffles installed over the DIMM connectors.
Installing, removing, and replacing compute node components
657
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...