Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0499
User Response
Information only; no action is required.
•
81030006-2101ffff : Sensor Sig Verify Fail has asserted.
Signature verification of one of the Firmware Volumes or Capsules in UEFI BIOS failed.
May also be shown as 810300062101ffff or 0x810300062101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0508
User Response
Automatic BIOS Recovery (ABR) should cause system to come up from UEFI image in backup
bank. Reflash UEFI image in the primary bank. If error does not persist no additional recovery
action is required.
•
8103010e-2581ffff : Sensor Memory Resized has deasserted.
This message is for the use case when an implementation has detected a Sensor has deasserted.
May also be shown as 8103010e2581ffff or 0x8103010e2581ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
463
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...