Prefix:
PLAT
ID:
0524
User Response
Complete the following steps until the problem is solved: 1. Check the Chassis Management Module
or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the
airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly
installed. 3. Make sure that the room temperature is within operating specifications. 4. If there are no
other thermal issues, replace the PCIe Card.
•
80070301-3103ffff : Sensor PCIE 3 Overtemp has transitioned to non-recoverable from a less
severe state.
Sensor PCIE 3 Overtemp has transitioned to critical from a less severe state. The compute node has
attempted a soft shutdown.
May also be shown as 800703013103ffff or 0x800703013103ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix:
PLAT
ID:
0524
User Response
Complete the following steps until the problem is solved: 1. Check the Chassis Management Module
or Flex System Manager event log for any fan- or cooling-related issues. 2. Make sure that the
airflow at the front and rear of the chassis is not obstructed and that fillers are in place and correctly
installed. 3. Make sure that the room temperature is within operating specifications. 4. If there are no
other thermal issues, replace the PCIe Card.
•
80070301-3104ffff : Sensor PCIE 4 Overtemp has transitioned to non-recoverable from a less
severe state.
Sensor PCIE 4 Overtemp has transitioned to critical from a less severe state. The compute node has
attempted a soft shutdown.
May also be shown as 800703013104ffff or 0x800703013104ffff
Severity
Error
Serviceable
Yes
329
Summary of Contents for Flex System x220
Page 1: ...Flex System x220 Compute Node Installation and Service Guide Machine Types 7906 2585 ...
Page 50: ...42 Flex System x220 Compute Node Installation and Service Guide ...
Page 54: ...46 Flex System x220 Compute Node Installation and Service Guide ...
Page 68: ...60 Flex System x220 Compute Node Installation and Service Guide ...
Page 644: ...636 Flex System x220 Compute Node Installation and Service Guide ...
Page 698: ...690 Flex System x220 Compute Node Installation and Service Guide ...
Page 705: ...Taiwan BSMI RoHS declaration Appendix B Notices 697 ...
Page 706: ...698 Flex System x220 Compute Node Installation and Service Guide ...
Page 713: ......
Page 714: ...Part Number 00YJ297 Printed in China 1P P N 00YJ297 1P00YJ297 ...